Applicable mediumLiquid fluid, slurry, suspension and other low-velocity media
Not applicable medium Solid medium
84409900 / 84403377
Overview:
YS-MFU series micro flow mass flowmeter sensor adopts patented single""measuring tube design, transmitter adopts full digital signal processing technology, the closed-loop control of the sensor, the real-time measurement of phase difference and frequency, the real-time calculation of fluid density, volume flow and component ratio, the calculation of temperature compensation and the calculation of pressure compensation are realized. The present domestic precise liquid or gas measurement of micro-diameter 0.8 mm (1/32 inch) and micro-flow 0.1 kg/hr (1.67 G/min) has been realized.
Product features:
●The error can reach ± 0.15% when the range ratio is 25:1, and the highest range ratio is 100:1
● No time drift and temperature drift, based on the advanced digital signal processing technology in frequency domain, to solve the time drift and temperature drift problems, to achieve high-precision real-time media mass flow and density calculation;
●Strong adaptability, using coupling vibration isolation patent technology, so that products on-site vibration interference is not sensitive to strong adaptability;
●Easy to install, with integrated transmitter, easy to install, no straight pipe section requirements, regardless of the sensor in the Upstream and downstream, fully compatible with similar products abroad.
微小流量质量流量计参考量程表
型号 | 通 径(mm) | 推荐流量范围(kg/h) | 最大流量范围(kg/ h) | 连接方式 |
YS-MFU-003 | 3 | 0~150(kg/h) | 0-180 | Welded Union 6 |
YS-MFU-006 | 6 | 0~480(kg/h) | 0-960 | Welded Union 10 |
YS-MFU-010 | 10 | 0~1800(kg/h) | 0-2100 | Flange DN10 |
Reference Range table for high pressure mass flowmeter:
●Accuracy of flow measurement | : | ±0.1-0.2% |
●Repeatability | : | ±0.05-0.1% |
●Repeatability | : | 0< ρ < 5g/ cm³ |
●Accuracy of density measurement | : | ±0.002g/cm³ |
●Temperature range | : | -200~350℃ |
●Accuracy of temperature measurement | : | ±1℃ |
●Measured medium temperature | : | -50℃ ~ 200℃ |
●Applicable ambient temperature | : | -40℃ ~80℃ |
●Material Quality | : | Fluid Connection, 316L housing, 304 |
●Working pressure | : | Conventional 4MPA, high pressure can be customized |
●Output Signal | : | 4-20mA DC current signal, 0-10KHz frequency pulse signal, |
Pulse equivalent signal, RS485 communication signal | ||
●Explosion proof grade | : | Exd(ib) II CT6 |
●Protection | : | IP67 |